Analyze a Gas Water Heater Not Heating

Posted by on May 20, 2015 in Gas Water Heater Repair Los Angeles, Water Heater Repair Los Angeles

A overwhelming majority of the water heaters Water Heater Repair Los Angeles receives repair inquiries for are gas water heaters. These are surely the top type. Listed below are several self diagnostic tips one can look at if the gas water heater is just not heating water whatsoever.

How to Self Diagnose a Los Angeles Gas Water Heater Repair

This might appear totally obvious, nonetheless examine to be certain the gas to the water heater is switched on. Switch the gas control knob to PILOT to keep the burner from igniting if looking within. Take off the metal cover at the lower part of the water heater and take a look to verify if the burner together with the pilot light are ignited.Gas Water Heater Repair Los Angeles

If the water heater’s pilot light has gone out, comply with the recommendations on the storage tank to relight it (we have the fundamental techniques to achieve this stated below). There does exist a chance that the gas inlet valve is shut partly or completely. If that is the situation, move the handle parallel to the line and ignite the pilot. If the pilot continue to not ignite, then the concern may perhaps be with the thermocouple. A good number of more recent water heaters possess a glow plug or spark igniter as an alternative to a pilot. Take note of the owner’s info for a guide.

If the burner is not on, replace the cover and ensure the thermostat is establish in the region of 120 degrees F. If it is not, change it, switch on a hot water faucet near the water heater, and after that wait around a couple of minutes to check if the water heater burner ignites. If it doesn’t ignite, keep the hot water running and attempt decreasing and then increasing the temperature setting on the dial until eventually the burner ignites.

If perhaps the burner ignites, replace the cover and switch the thermostat once again to the ideal setting. If the burner does not ignite, allow us to look at the water heater. The heater’s thermostat may very well be faulty. A thermostat switch should really be done by us.

Do you smell gas? If a odor very much like garlic is found, switch the gas valve control to the OFF status. Hang on and check if the gas odor has dissipated prior to relighting the pilot. If it does not go away, without delay shut off the gas supply valve, air out the room as best as is possible and contact the gas utility company.

Pilot Light Doesn’t Stay Lit

Attempt to relight the water heater initially. In primary terms, move the water heater’s gas valve to the OFF placement and after that to the PILOT placement. Push the pilot button down to light it, and then hang on until a status light indicates the dial may be switched from PILOT to ON.

In the event the pilot light continues going out, possibly the orifices could possibly be unclean and blocked, that may make the flame too little to remain lit. Examine to make certain there is no noticeable dirt and debris clogging it.

In the event everything seems to be clean, the situation may perhaps be with the thermocouple. This is the piece that runs from the temperature control directly into the flame of a pilot light and allows the main burner fire up when the water temperature has moved too low. The pilot light might be impacted if the thermocouple is flawed or doesn’t come into contact with the pilot flame. Many people could possibly feel at ease changing a thermocouple, but Gas Water Heater Repair Los Angeles would rather you contact us to assist.

Decreased gas pressure or a not working gas control valve might also result in a pilot light to go out often. Contact us if you believe that this is the event.